Capa do livro de THERAPIES DELIVERED BY AUTOMATIC IMPLANTABLE DEFIBRILLATORS
Título do livro:

THERAPIES DELIVERED BY AUTOMATIC IMPLANTABLE DEFIBRILLATORS

INCIDENCE AND IMPACT ON SURVIVAL

Our Knowledge Publishing (2021-09-13 )

Books loader

Omni badge Apto para vale
ISBN- 1 3:

978-620-4-08069-7

ISBN- 1 0:
6204080695
EAN:
9786204080697
Idioma do livro:
Inglês
Anotações e citações/ texto breve:
Appropriate effective therapy is the essential goal of the implantable automatic defibrillator. The occurrence of inappropriate therapy is a potentially serious event. Methods:We conducted a study that included 80 patients implanted with ICDs in the cardiology department of Habib Thameur Hospital in Tunis between January 2010 and June 2019. Results:The median age of the patients was 58 years (52.25-65.75) with a sex ratio of 12.1H/F. During a median follow-up of 48 months, 695 therapies were recorded: 62% anti-tachycardia pacing (ATP) and 38% shocks with a predominance of appropriate therapies (87.8%).The incidence of therapies was 4.72 therapies/patient-year at 1 year, 3.28 therapies/patient-year at 3 years and 0.78 therapies/patient-year at 5 years. In multivariate analysis, the independent predictors of death were inappropriate therapy (RR = 1.102 with a 95% CI of (1.026-1.184), p=0.008), ischemic heart disease (RR = 2.965 with a 95% CI of (0.931-9.444), p=0.066), and LVEF less than 29% (RR = 2.340 with a 95% CI of (0.942-5.809), p=0.067).
Editora:
Our Knowledge Publishing
Website:
https://sciencia-scripts.com
Por (autor):
Sofien Kamoun, Imtinene Ben Mrad, Marwa Ben Dou Dou
Número de páginas:
96
Publicado em:
2021-09-13
Stock:
Disponível
Categoria:
Ocupações médicas especializadas
Preço:
54.90 €
Palavras chave:
Incidence - Defibrillator - Prevention - Survival - Hospitalization

Books loader

Adyen::diners Adyen::jcb Adyen::discover Adyen::amex Adyen::mc Adyen::visa Adyen::cup Adyen::ach Adyen::unionpay Adyen::paypal PayPal Transferência Bancária

  0 produtos no carrinho
Editar carrinho
Loading frontend
LOADING